New Jersey tap water / Water systems
New Jersey American Water, Coastal North system: 2025 water quality report results
In its 2025 water quality report, the New Jersey American Water, Coastal North system reported PFOA at 8.7 ppt and PFOS at 2.6 ppt (highest running annual average). PFOA is below New Jersey's limit but above the federal limit; PFOS is below both the New Jersey and federal limits. Lead at the 90th percentile of home taps: 2 ppb. Hardness: up to 140 mg/L (moderately hard to hard).
2025 results against New Jersey and federal limits
Highest running annual average in the 2025 report; range in the report: not detected to 8.7 ppt
Below New Jersey's limit, above the federal limit
Highest running annual average in the 2025 report; range in the report: not detected to 2.6 ppt
Below both limits
Each bar shows the highest running annual average reported for this system, in parts per trillion (ppt), against both limits. The darker band is the range of results the report lists; the status compares the reported value, not the top of the range, with the limits.
| Measure | Reported | NJ limit | Federal limit | Status |
|---|---|---|---|---|
| PFOAPerfluorooctanoic acid | 8.7 pptRange in the report: not detected to 8.7 ppt | 14 ppt | 4 ppt | Below NJ limit, above federal |
| PFOSPerfluorooctane sulfonic acid | 2.6 pptRange in the report: not detected to 2.6 ppt | 13 ppt | 4 ppt | Below both limits |
| HFPO-DA, PFHxS and PFNA | Not detected | |||
| Lead90th percentile of home taps | 2 ppb | Action level 15 ppb (10 ppb from November 2027) | Below action level | |
| 1,2,3-Trichloropropane | 0.01 ppbHighest compliance result, range ND to 0.01 ppb, 2025 | 0.03 ppb | None | Below New Jersey limit |
| ChlorideSecondary standard | 119 ppmHighest compliance result, range ND to 119 ppm, 2023-2025 | 250 ppm recommended upper limitNot enforceable | 250 ppmSecondary standard, not enforceable | Below recommended limit |
| SodiumSecondary standard | 69.9 ppmHighest compliance result, range 4.1 to 69.9 ppm, 2023-2025 | 50 ppm recommended upper limitNot enforceable | None | Above recommended limit |
| Hardness | Up to 140 mg/L (8.2 gpg)Ranged from 72 to 140 mg/L at the treatment plants in 2023-2025 | 250 mg/L recommended upper limitFor taste and appearance; not enforceable | None | Class: moderately hard to hardA description, not a limit comparison |
The 2025 report doesn't list arsenic. New Jersey sets its own limits for arsenic (stricter than the federal one) and 1,2,3-trichloropropane (no federal limit); its sodium and chloride limits are recommended upper limits, not enforceable. Federal limits as of November 2026.
According to EPA, lead gets into drinking water when plumbing that contains lead corrodes, and where a home has a lead service line, that pipe is typically the largest source. So a home's own tap can differ from the system-wide 90th percentile.
Other PFAS detected in EPA's nationwide testing (UCMR 5), not charted because the figure isn't a compliance result: 6:2 FTS, PFBS, PFHpA, PFHxA and PFPeA.
EPA kept its 4 ppt limits for PFOA and PFOS. Utilities must meet them by 2029; EPA has proposed letting systems request until 2031. In May 2026, EPA proposed withdrawing its national limits for PFNA, PFHxS, GenX (HFPO-DA) and a combined limit for PFAS mixtures. The proposal isn't final yet; EPA plans to decide in 2026. New Jersey's own PFNA limit is unaffected. (Status as of November 2026.)
Compare the NJ American Water, Coastal North system with other New Jersey water systems in one table of 2025 PFAS results, or see hardness across the same systems.
Filters certified for PFOA
If you want to reduce PFOA at home, look for a filter certified to NSF/ANSI Standard 53 or 58 with a PFOA reduction claim, and check the claim on the certifier's own listing. Certification shows the filter reduces these chemicals; it doesn't guarantee levels below the federal limit.
| Filter | Type | Certified by | Reduction claims |
|---|---|---|---|
| Aquasana Claryum 3-Stage | Under-sink | WQANSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 401 | PFOA and lead · data sheet |
| Aquasana Claryum 3-Stage Max Flow | Under-sink | WQANSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 401 | PFOA and lead · data sheet |
| Aquasana Claryum 2-Stage | Under-sink | WQANSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 401 | PFOA and lead · data sheet |
| Aquasana Claryum Direct Connect | Under-sink | IAPMONSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 401 | PFOA and lead · data sheet |
| Aquasana OptimH2O whole house system (EQ-OPTM) | Whole house | IAPMONSF/ANSI 53 | PFOA and lead · data sheet |
| AquaTru Classic countertop RO | Reverse osmosis | IAPMONSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 58, NSF/ANSI 401 | PFOA and lead · manufacturer page |
| ZeroWater 5-Stage filter (pitchers and dispensers) | Pitcher | IAPMONSF/ANSI 42, NSF/ANSI 53 | PFOA and lead · data sheet |
| ZeroWater ExtremeLife faucet mount (ZFM-400, filter ZRFM-001) | Faucet mount | WQANSF/ANSI 42, NSF/ANSI 53 | PFOA · data sheet |
| PUR PLUS pitcher filter (PPF951K) | Pitcher | IAPMONSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 401 | total PFAS (test mix includes PFOA) and lead · data sheet |
We list a filter only when its certification document backs the claim (how we choose products). Replace cartridges on schedule; a used-up filter stops working.
Towns served by the New Jersey American Water, Coastal North system
- Middletown tap water
- Long Branch tap water
- Neptune tap water
- Ocean Township tap water
- Tinton Falls tap water
- Howell tap water (mostly served)
- Asbury Park tap water
- Eatontown tap water
- West Long Branch tap water
- Rumson tap water
- Fair Haven tap water
- Oceanport tap water
- Little Silver tap water
Water sources
Source water comes from the following aquifers and/or surface water bodies: Potomac-Raritan-Magothy Aquifer (PRM), Englishtown aquifer, Kirkwood-Cohansey aquifer, Mount Laurel-Wenonah aquifer, Vincentown aquifer, Old Bridge aquifer & Farrington aquifer, Glendola Reservoir, the Manasquan River/Reservoir, the Shark River, and the Swimming River/Reservoir.
Source. 2025 water quality report, New Jersey American Water, Coastal North system. Also: EPA Safe Drinking Water Information System; EPA UCMR 5.
Checked against the original report in September, October and November 2026. See how we check the data. Found an error? Tell us.